| by Admin

VFD Panel | Helical Engineers | Electrical panel in Mohali , Electrical Automation in Mohali  - GL99809

Description-
Variable frequency drive control panel (also named VFD panel, AC drive electrical control panel) is consisted of inner VFD inside the cabinet with external control, protect, display and other electrical, it's an frequency conversion device to control three phase AC motor (including fans and pumps) in variable speed to save energy.

Why VFDs Panels?

The two main features of VFD are adjustable speeds and soft start/stop capabilities. These two features make VFD’s a powerful controller to control the AC motors.

Benefits Of VFD:

Variable frequency drives not only offer adjustable speeds for accurate and precise control applications, but also have more benefits in terms of process control and conservation of energy. Some of these are given below.

Energy Saving

More than 65% of the power is consumed by electric motors in industries. Both magnitude and frequency control technique to vary the speed consumes less power when variable speed is required by the motor. So a great amount of energy is conserved by these VFD’s.

Closed Loop Controlling

VFD allows accurate positioning of the motor speed by continuously comparing with reference speed even at changes in the loading conditions and input disturbances like voltage fluctuations.

Limits Starting Current

Induction motor draws current which is of 6 to 8 times the nominal current at starting. Compared to conventional starters, VFD’s gives better results because it delivers low frequency at the time of starting. Due to low frequency, the motor draws less current and this current never exceeds its nominal rating at starting as well as operating.

Smooth Operation

It offers smooth operations at starting and stopping and also reduces thermal and mechanical stress on motors and belt drives.

High Power Factor

Inbuilt power factor correction circuit in the DC link of VFD reduces the need for additional power factor correction devices. The power factor for the induction motor is very low for particularly no-load application, while at full load, it is 0.88 to 0.9. Low power factor results in poor utilization of power due to high reactive losses.

Easy Installation

Pre-programmed and factory wired VFD’s offers easy way for connection and maintenance.

Purge and Pressurized panels

Flameproof and Explosion Proof Panels

SIL Safety PLC systems

Distributed Control Systems

IEC 61439 Type Tested Assembly panels

Technical Specification:

We offer VFD Panels conforming to the following specifications:

System3 Phase, 3 or 4 wire, 50Hz
Rated CurrentUp to 5000 Amps
Operational Voltage230/380/415/440v AC
Rated Insulation1000v
Rated Service Voltage690v
Ambient Temperature45 Deg C
Short Time CurrentUp to 65KA for 1Sec, 105KA peak
Degree of ProtectionIP42-IP65
Form of SeparationUp to 3B/4B
Type Tested forShort Time Current withstand Temperature Rise Degree of Protection
Bus Bar SystemInterleaved above 3200A
Bus BarAluminum or Copper
Feeder ConfigurationSemi Dropout or Fix Type



Share this page